Date:05-15-2024STATE OF CALIFORNIA 
LAST AND NEXT SAMPLE REPORT
SYSTEM NO.:4200854SYSTEM NAME:IMERYS FILTRATION MINERALS, INCCOUNTY:SANTA BARBARA 
SOURCE NO.:036SOURCE NAME:WELL 36SOURCE CLASS:NCNCSTATUS:A



Click to hide / show columns: PS Codes | Group Name | Analyte Number | Analyte Name | Detected Level |Less Than | RL | Unit | MCL | DLR | Last Sampled | Frequency | Next Due | Notes

PS Codes Group Name Analyte Number Analyte Name Results Unit MCL DLR Last Sampled Frequency Next Due Notes
Detected Level Less Than RL
CA4200854_036_036 SECONDARY/GP-202503 1928 ALKALINITY, BICARBONATE 410.000 8.200 MG/L 03-08-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202512 1919 CALCIUM 240.000 0.100 MG/L 12-07-2022 36 2025/12
CA4200854_036_036 SECONDARY/GP-202503 1929 ALKALINITY, CARBONATE < 8.200 MG/L 03-08-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202503 1017 CHLORIDE 100.000 0.500 MG/L 500 03-08-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202503 1905 COLOR 15.000 1.000 UNITS 15 03-14-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202512 1022 COPPER, FREE 10.000 10.000 UG/L 1000 50 12-07-2022 36 2025/12
CA4200854_036_036 SECONDARY/GP-202503 2905 FOAMING AGENTS (SURFACTANTS) < 0.200 MG/L .5 03-08-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202503 1915 HARDNESS, TOTAL (AS CACO3) 570.000 0.500 MG/L 03-08-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202503 1021 HYDROXIDE AS CALCIUM CARBONATE < 8.200 MG/L 03-08-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202512 1028 IRON 440.000 50.000 UG/L 300 100 12-07-2022 36 2025/12
CA4200854_036_036 SECONDARY/GP-202512 1031 MAGNESIUM 110.000 0.050 MG/L 12-07-2022 36 2025/12
CA4200854_036_036 SECONDARY/GP-202512 1032 MANGANESE < 10.000 UG/L 50 20 12-07-2022 36 2025/12
CA4200854_036_036 SECONDARY/GP-202503 1920 ODOR < 1.000 TON 3 1 03-14-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202503 1925 PH 7.660 0.050 pH 03-08-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202512 1050 SILVER < 10.000 UG/L 100 10 12-07-2022 36 2025/12
CA4200854_036_036 SECONDARY/GP-202512 1052 SODIUM 100.000 0.500 MG/L 12-07-2022 36 2025/12
CA4200854_036_036 SECONDARY/GP-202503 1064 CONDUCTIVITY @ 25 C UMHOS/CM 1260.000 1.000 UMHO/CM 1600 03-08-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202503 1055 SULFATE 150.000 1.000 MG/L 500 .5 03-08-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202503 1930 TDS 800.000 50.000 MG/L 1000 03-08-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202503 0100 TURBIDITY 5.600 0.100 NTU 5 .1 03-14-2022 36 2025/03
CA4200854_036_036 SECONDARY/GP-202512 1095 ZINC < 50.000 UG/L 5000 50 12-07-2022 36 2025/12
CA4200854_036_036 INORGANIC-202512 1002 ALUMINUM < 50.000 UG/L 1000 50 12-07-2022 36 2025/12
CA4200854_036_036 INORGANIC-202512 1074 ANTIMONY, TOTAL < 2.000 UG/L 6 6 12-07-2022 36 2025/12
CA4200854_036_036 INORGANIC-202512 1005 ARSENIC 5.000 2.000 UG/L 10 2 12-07-2022 36 2025/12
CA4200854_036_036 INORGANIC-202512 1010 BARIUM 110.000 10.000 UG/L 1000 100 12-07-2022 36 2025/12
CA4200854_036_036 INORGANIC-202512 1075 BERYLLIUM, TOTAL < 1.000 UG/L 4 1 12-07-2022 36 2025/12
CA4200854_036_036 INORGANIC-202512 1015 CADMIUM 1.700 1.000 UG/L 5 1 12-07-2022 36 2025/12
CA4200854_036_036 INORGANIC-202512 1020 CHROMIUM < 10.000 UG/L 50 10 12-07-2022 36 2025/12
CA4200854_036_036 INORGANIC-202503 1025 FLUORIDE 0.410 0.050 MG/L 2 .1 03-08-2022 36 2025/03
CA4200854_036_036 INORGANIC-202512 1030 LEAD < 1.000 UG/L 5 12-07-2022 36 2025/12
CA4200854_036_036 INORGANIC-202512 1035 MERCURY < 0.200 UG/L 2 1 12-07-2022 36 2025/12
CA4200854_036_036 INORGANIC-202512 1036 NICKEL 21.000 10.000 UG/L 100 10 12-07-2022 36 2025/12
CA4200854_036_036 INORGANIC-202512 1045 SELENIUM 5.500 2.000 UG/L 50 5 12-07-2022 36 2025/12
CA4200854_036_036 INORGANIC-202512 1085 THALLIUM, TOTAL < 1.000 UG/L 2 1 12-07-2022 36 2025/12
CA4200854_036_036 NITRATE/NITRITE-202312 1040 NITRATE < 0.400 MG/L 10 .4 12-07-2022 12 2023/12 DUE NOW
CA4200854_036_036 NITRATE/NITRITE-202503 1041 NITRITE < 0.050 MG/L 1 .4 03-14-2022 36 2025/03
CA4200854_036_036 REGULATED SOC-202305 2414 1,2,3-TRICHLOROPROPANE < 0.005 UG/L 0.005 02-15-2023 3 2023/05 DUE NOW
PS Codes Group Name Analyte Number Analyte Name Detected Level Less Than RL Unit MCL DLR Last Sampled Frequency Next Due Notes

RL – Reporting Level means the level to which the laboratory reported the presence of an analyte. For radionuclides, Reporting Level is the MDA95.

DLR – Detection Limit for purposes of Reporting (DLR) means the designated minimum level at or above which any analytical finding of a contaminant in drinking water resulting from monitoring required under Chapter 15 of Title 22 shall be reported to the State Board (California Code of Regulations Section § 64400.34)

For addtional definitions, please refer to our data dictionary.